The universal device with standard integrated temperature compensation for saturated steam and optionally pressure compensation for superheated steam, gases, wet gases

Measuring sensor VFM 4000

Process connection sandwich version EN 1092-1 : DN15...100

Process connection sandwich version ASME B16.5 : 1/2...4"

Process connection flange version EN 1092-1 : DN15...300

Process connection flange version ASME B16.5 : 1/2...12"

Process temperature : -40...+240°C; -40...+464°F

Ambient temperature (Non Ex) : -40...+85°C; -40...+185°F

Materials sensor : 1.4404/316L, Hastelloy C22

Reduction of nominal diameter : 1 or 2 steps reduced bore meter (flange version)

Signal converter VFC 200 C/F

Measuring accuracy : Re > 20000 ±0.75% for liquids

    Re > 20000 ±1% for gases and steam

    10000 < Re < 20000 ±2% for liquids, gases and steam

Outputs : 4-20 mA, pulse/frequency/ status/limit switch

Power supply : 12...30 VDC

Protection category : IP66/67

Housing material : Aluminum, stainless steel

Produk Terkait